CAMSHAFT POSITION SENSOR INSPECTION


  1. INSPECT CAMSHAFT POSITION SENSOR

    A01DZS5E08

    1. Measure the resistance between the terminals.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 2 Approx. 20°C (68°F) 950 to 1.250 Ω

      • If the result is not as specified, replace the sensor.