COMPRESSOR(for 2ZR-FE) REMOVAL

PROCEDURE

  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFC-134a(R134a))

  2. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFO-1234yf(R1234yf))

  3. REMOVE V-RIBBED BELT

  4. DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY

    1. E261283

      Remove the bolt and disconnect the discharge hose sub-assembly from the compressor assembly with pulley.

    2. Remove the O-ring from the discharge hose sub-assembly.

      Note:

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

  5. DISCONNECT SUCTION HOSE SUB-ASSEMBLY

    1. E261284

      Remove the bolt and disconnect the suction hose sub-assembly from the compressor assembly with pulley.

    2. Remove the O-ring from the suction hose sub-assembly.

      Note:

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

  6. REMOVE COMPRESSOR ASSEMBLY WITH PULLEY

    1. E261285

      Disconnect the connector.

    2. Disengage the clamp.

    3. E261286C05
      V100135

      Bolt

      V100136

      Nut

      Remove the 2 bolts and 2 nuts.

    4. E261287

      Using an E8 "TORX" socket, remove the 2 stud bolts.

    5. Remove the compressor assembly with pulley.