ECM INSTALLATION

PROCEDURE

  1. INSTALL ECM

    1. Install the No. 1 ECM bracket and No. 2 ECM bracket to the ECM with the 4 screws.

      3.0 N*m

      31 kgf*cm

      27 in.*lbf

    2. Install the ECM with bracket with the 3 bolts.

      6.5 N*m

      66 kgf*cm

      58 in.*lbf

    3. Connect the 2 ECM connectors and lower the 2 levers.

      Note:
      • When connecting the ECM connector, make sure that dirt, water or other foreign matter is not stuck between the ECM connector and ECM.

      • Make sure that the 2 levers are securely lowered.

  2. INSTALL AIR CLEANER CASE

  3. INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

  4. INSTALL AIR CLEANER CAP SUB-ASSEMBLY

  5. INSTALL NO. 1 ENGINE COVER

  6. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click hereClick hereClick hereClick here

  7. PERFORM REGISTRATION

  8. PERFORM INITIALIZATION

  9. PERFORM THROTTLE VALVE FULLY CLOSED POSITION LEARNING