ECM INSTALLATION
PROCEDURE
INSTALL ECM
Install the No. 1 ECM bracket and No. 2 ECM bracket to the ECM with the 4 screws.
3.0 N*m
31 kgf*cm
27 in.*lbf
Install the ECM with bracket with the 3 bolts.
6.5 N*m
66 kgf*cm
58 in.*lbf
Connect the 2 ECM connectors and lower the 2 levers.
Note:When connecting the ECM connector, make sure that dirt, water or other foreign matter is not stuck between the ECM connector and ECM.
Make sure that the 2 levers are securely lowered.
INSTALL AIR CLEANER CASE
INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
INSTALL AIR CLEANER CAP SUB-ASSEMBLY
INSTALL NO. 1 ENGINE COVER
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
PERFORM REGISTRATION
PERFORM INITIALIZATION
PERFORM THROTTLE VALVE FULLY CLOSED POSITION LEARNING