LED HEADLIGHT SYSTEM
The light control ECU operates in fail-safe mode if an abnormal condition such as those listed below has been detected.
| Item | Abnormality Detection Condition | Return Condition |
|---|---|---|
| Abnormal input voltage (Low input voltage) | If the power source voltage is too low (6 to 9 V), headlight operation will stop. | If the voltage returns to 9 V or more, headlight operation will resume. |
| Abnormal output |
|
Light control switch is turned off to head. |
*: When the headlights are on and the input voltage becomes between 6 and 10 V, the headlights dim.