DYNAMIC REAR STEERING SYSTEM DATA LIST / ACTIVE TEST

Note

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

Tech Tips

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


  1. DATA LIST


    1. Turn the engine switch off.

    2. Connect the GTS to the DLC3.

    3. Turn the engine switch on (IG).

    4. Turn the GTS on.

    5. Enter the following menus: Chassis / DRS / Data List.

    6. According to the display on the GTS, read the Data List.


      Chassis > DRS > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Rear Wheel Angle(Motor Resolver) Rear wheel angle (motor resolver)

      Min.: -8.00 deg

      Max.: 7.99 deg

      -1.0 to 1.0 deg -
      Rear Wheel Angle Changing Speed Rear wheel angle changing speed

      Min.: -8.00 deg/s

      Max.: 7.99 deg/s

      -8.00 to 7.99 deg/s -
      Vehicle Speed Rear wheel angle changing speed

      Min.: 0.00 km/h (0 mph)

      Max.: 327.67 km/h (203 mph)

      Actual vehicle speed -
      Starting Status Starting status Stop or Starting-up

      Engine stopped: Stop

      Engine running: Starting-up

      -
      IG Power Supply Voltage IG power supply voltage

      Min.: 0.00 V

      Max.: 255.99 V

      10.5 to 16 V -
      PIG Power Supply Voltage PIG power supply voltage

      Min.: 0.00 V

      Max.: 255.99 V

      11 to 14 V -
      Power Supply Status Power supply status Unreceived, Prompt Stop, Cur Pos Stop, N Pos Stop or Normal Normal If the result is not as specified, the vehicle power supply voltage may be low
      Limited Current Limited current

      Min.: -256.00 A

      Max.: 255.99 A

      -60 to 60 A -
      Voltage before Pressure Rising Voltage before pressure rising

      Min.: 0.00 V

      Max.: 255.99 V

      11 to 14 V -
      Voltage after Pressure Rising Voltage after pressure rising

      Min.: 0.00 V

      Max.: 255.99 V

      11 to 14 V -
      System Heavily-loaded Status System heavily-loaded status OFF or ON OFF -
      ECU Substrate Temperature ECU substrate temperature

      Min.: -256.00°C (-428°F)

      Max.: 255.99°C (492°F)

      -40 to 120°C (-40 to 248°F) -
      Motor Temperature(ECU Calculated Value) Motor temperature (ECU calculated value)

      Min.: -256.00°C (-428°F)

      Max.: 255.99°C (492°F)

      70 to 140°C (158 to 284°F) -
      ECU Substrate Temperature(ECU Calculated Value) ECU substrate temperature (ECU calculated value)

      Min.: -256.00°C (-428°F)

      Max.: 255.99°C (492°F)

      -40 to 120°C (-40 to 248°F) -
      Ambient Temperature Ambient temperature

      Min.: -40°C (-40°F)

      Max.: 50°C (122°F)

      Same as ambient temperature -
      System Overheat Status System overheat status Normal, Overheat-Weak or Overheat-Strong Normal If the result is not as specified, the applied load to the DRS system may be high
      Motor Resolver Electrical Angle Motor resolver electrical angle

      Min.: 0.00 deg

      Max.: 359.99 deg

      0.00 to 359.99 deg -
      Changing Amount of Motor Resolver Electrical Angle Changing amount of motor resolver electrical angle

      Min.: -180.00 deg

      Max.: 179.99 deg

      -30 to 30 deg -
      Motor Resolver SIN Phase Shaped Width Motor resolver SIN phase amplitude

      Min.: -5.00 V

      Max.: 4.99 V

      -3.5 to 3.5 V -
      Motor Resolver SIN Phase Offset Motor resolver SIN phase offset

      Min.: 0.00 V

      Max.: 19.99 V

      8 to 12 V -
      Motor Resolver COS Phase Shaped Width Motor resolver COS phase amplitude

      Min.: -5.00 V

      Max.: 4.99 V

      -3.5 to 3.5 V -
      Motor Resolver COS Phase Offset Motor resolver COS phase offset

      Min.: 0.00 V

      Max.: 19.99 V

      8 to 12 V -
      Motor Resolver Shaped Width Squared Sum Sum of squares of motor resolver amplitudes

      Min.: 0.00 V^2

      Max.: 25.00 V^2

      5.7 to 12.3 V^2 -
      Stroke Resolver Electrical Angle Stroke resolver electrical angle

      Min.: 0.00 deg

      Max.: 359.99 deg

      25 to 325 deg -
      Standard Value of Stroke Resolver Electrical Angle Standard value of stroke resolver electrical angle

      Min.: 0.00 deg

      Max.: 359.99 deg

      170 to 190 deg -
      Stroke Resolver SIN Phase Shaped Width Stroke resolver SIN phase amplitude

      Min.: -5.00 V

      Max.: 4.99 V

      -3.5 to 3.5 V -
      Stroke Resolver SIN Phase Offset Stroke resolver SIN phase offset

      Min.: 0.00 V

      Max.: 19.99 V

      8 to 12 V -
      Stroke Resolver COS Phase Shaped Width Stroke resolver COS phase amplitude

      Min.: -5.00 V

      Max.: 4.99 V

      -3.5 to 3.5 V -
      Stroke Resolver COS Phase Offset Stroke resolver COS phase offset

      Min.: 0.00 V

      Max.: 19.99 V

      8 to 12 V -
      Stroke Resolver Shaped Width Squared Sum Sum of squares of stroke resolver amplitudes

      Min.: 0.00 V^2

      Max.: 25.00 V^2

      5.7 to 12.3 V^2 -
      Motor Resolver Neutral Compensation Value Motor resolver neutral compensation value

      Min.: 0.00 deg

      Max.: 359.99 deg

      0 to 359.99 deg -
      Rear Wheel Angle Taking Status on Start-up Rear wheel angle taking status on start-up Unknown, Motor Resolver or Stroke Resolver Motor Resolver If the result is not as specified, the DRS system may be malfunctioning
      Rear Wheel Target Angle(L-CAN) Rear wheel target angle (L-CAN)

      Min.: -8.00 deg

      Max.: 7.99 deg

      -1.0 to 1.0 deg -
      Rear Wheel Target Angle(G-CAN) Rear wheel target angle (G-CAN)

      Min.: -8.00 deg

      Max.: 7.99 deg

      -1.0 to 1.0 deg -
      Rear Wheel Angle(Stroke Sensor) Rear wheel angle (stroke sensor)

      Min.: -8.00 deg

      Max.: 7.99 deg

      -1.0 to 1.0 deg -
      Motor U Phase Voltage Motor U phase voltage

      Min.: 0.00 V

      Max.: 255.99 V

      0 to 34 V -
      Motor V Phase Voltage Motor V phase voltage

      Min.: 0.00 V

      Max.: 255.99 V

      0 to 34 V -
      Motor W Phase Voltage Motor W phase voltage

      Min.: 0.00 V

      Max.: 255.99 V

      0 to 34 V -
      Motor U Phase Current Motor U phase current

      Min.: -256.00 A

      Max.: 255.99 A

      -57 to 57 A -
      Motor V Phase Current Motor V phase current

      Min.: -256.00 A

      Max.: 255.99 A

      -57 to 57 A -
      Motor W Phase Current Motor W phase current

      Min.: -256.00 A

      Max.: 255.99 A

      -57 to 57 A -
      Motor U Phase Duty Motor U phase duty

      Min.: 0.00 %

      Max.: 100.00 %

      9 to 91 % -
      Motor V Phase Duty Motor V phase duty

      Min.: 0.00 %

      Max.: 100.00 %

      9 to 91 % -
      Motor W Phase Duty Motor W phase duty

      Min.: 0.00 %

      Max.: 100.00 %

      9 to 91 % -
      Motor Rotation Speed Motor rotation speed

      Min.: -32768 deg/s

      Max.: 32767 deg/s

      -32768 to 32767 deg/s -
      Actuator Operation Amount Actuator operation amount Too Little, Normal, Malfunction or Too Much Normal -
      Limited Control Count(Overheat-Weak) Limited control count (overheat-weak)

      Min.: 0

      Max.: 225

      0 -
      Limited Control Count(Overheat-Strong) Limited control count (overheat-strong)

      Min.: 0

      Max.: 225

      0 -
      N Pos Stop Control Count N pos stop control count

      Min.: 0

      Max.: 225

      0 -
      Cur Pos Stop Control Count Cur pos stop control count

      Min.: 0

      Max.: 225

      0 -
      Prompt Stop Control Count Prompt stop control count

      Min.: 0

      Max.: 225

      0 -
      Power Supply Voltage Lowering Control Count Power supply voltage lowering control count

      Min.: 0

      Max.: 225

      0 -
      Limited Control Count(System Heavily-loaded) Limited control count (system heavily-loaded)

      Min.: 0

      Max.: 225

      0 -
      VGRS System Status VGRS system status Normal or Malfunction Normal -
      Number of DTC Number of DTC

      Min.: 0

      Max.: 225

      0 -