BLIND SPOT MONITOR SENSOR INSTALLATION
PROCEDURE
INSTALL BLIND SPOT MONITOR SENSOR LH
Note:Avoid any impact to the blind spot monitor sensor LH.
Do not drop the blind spot monitor sensor LH. If it is dropped, replace it with a new one.
Connect the connector.
Install the blind spot monitor sensor LH with the 3 nuts.
10 N*m
102 kgf*cm
7 ft.*lbf
INSTALL BLIND SPOT MONITOR SENSOR RH
Note:Avoid any impact to the blind spot monitor sensor RH.
Do not drop the blind spot monitor sensor RH. If it is dropped, replace it with a new one.
Connect the connector.
Install the blind spot monitor sensor RH with the 3 nuts.
10 N*m
102 kgf*cm
7 ft.*lbf
INSTALL REAR BUMPER COVER
INSTALL REAR QUARTER PANEL MUDGUARD LH (w/ Mudguard)
INSTALL REAR QUARTER PANEL MUDGUARD RH (w/ Mudguard)
Tip:Use the same procedure described for the LH side.
PERFORM BLIND SPOT MONITOR BEAM AXIS INSPECTION
PERFORM DIAGNOSTIC SYSTEM CHECK