CHARGING SYSTEM TERMINALS OF ECU
CHECK GENERATOR CONTROL ECU ASSEMBLY
Tip:The standard normal voltage between each pair of generator control ECU assembly terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals displayed in the Specified Condition column. The illustration above can be used as a reference to identify the generator control ECU assembly terminal locations.
Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
A52-1 (ACC) - Body ground
GR - Body ground
Constant power source
Ignition switch ACC
11 to 14 V
A52-2 (CA3N) - A52-3 (CA3P)
SB - B
CAN communication signal
Ignition switch off
(while CAN communication stopped)
108 to 132 Ω
A52-5 (AM21) - Body ground
P - Body ground
Constant power source
Always
11 to 14 V
A52-6 (LIN1) - Body ground
G - Body ground
LIN communication signal
Ignition switch off
(while LIN communication stopped)
10 kΩ or higher
A52-9 (INH) - Body ground
R - Body ground
Wiper operation signal
Ignition switch ON, wiper switch HI
11 to 14 V