CRANKSHAFT POSITION SENSOR INSPECTION
PROCEDURE
INSPECT CRANK POSITION SENSOR
-
*a
Component without harness connected
(Crank Position Sensor)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 (NE+) - 2 (NE-)
Cold
1630 to 2740 Ω
Hot
2065 to 3225 Ω
Note:In the table above, the terms "Cold" and "Hot" refer to the temperature of the sensor. "Cold" means approximately -10 to 50°C (14 to 122°F). "Hot" means approximately 50 to 100°C (122 to 212°F).
If the resistance is not as specified, replace the crank position sensor.
-