STOP AND START SYSTEM Stop and Start System does not Operate (Battery Condition)

DTC Code DTC Name
Stop and Start System does not Operate (Battery Condition)

DESCRIPTION

When the stop and start system does not operate, check whether the operation is prohibited because the battery conditions are not met.

Tip:

Data List items:

  • Oper Permission (Battery)

  • Oper Permission (Start Min Volt 1)

  • Oper Permission (Start Min Volt 2)

  • Oper Permission (Start Min Volt 3)

  • Oper Permission (Start Min Volt 4)

  • Oper Permission (Battery Current)

  • Oper Permission (Integrated Current)

  • Oper Prohibition (Jump Start)

  • Oper Prohibition (Manual Start)

PROCEDURE

  1. CHECK DTC OUTPUT

    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Stop and Start / Trouble Codes.

    5. Read the DTCs.

      Table 1. Result

      Result

      Proceed to

      DTC is not output

      A

      DTC is output

      B

    GO TO DIAGNOSTIC TROUBLE CODE CHART

  2. READ VALUE USING GTS

    1. Enter the following menus: Powertrain / Stop and Start / Data List.

    2. Check the following items on the GTS display.

      Table 2. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Oper Permission (Battery)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Stop and start control is permitted due to battery condition, or Active Test (forced permission) is performed

      -

      Oper Permission (Start Min Volt 1)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Battery temperature is 0°C (32°F) or less and the minimum voltage at starter ON is the threshold value or higher

      If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

      Oper Permission (Start Min Volt 2)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage at starter ON is the threshold value or higher

      If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

      Oper Permission (Start Min Volt 3)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Battery temperature is 0°C (32°F) or less and the minimum voltage right after engine cranking is the threshold value or higher

      If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

      Oper Permission (Start Min Volt 4)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage right after engine cranking is the threshold value or higher

      If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

      Oper Permission (Battery Current)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Battery discharge current is -125 A or less

      Engine stop and start ECU calculated value

      Oper Permission (Integrated Current)

      Permission of stop and start control based on the integrated current value conditions/

      NG / OK

      OK: Integrated current value more than specified

      The status depend on the value of "Integrated Current", and OK/NG threshold differs according to the battery temperature.

      Oper Prohibition (Jump Start)

      Prohibition of stop and start control based on the jump start conditions/

      Permit / Prohibit

      Prohibit: Engine started with the engine hood open and the ignition switch turned to START

      When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.

      Oper Prohibition (Manual Start)

      Prohibition of stop and start control based on the manual start conditions/

      Permit / Prohibit

      Prohibit: During manual start

      When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.

      Conditions for Manual Start:

      • Clutch start switch OFF or vehicle speed

      • Neutral position sensor (neutral position switch) OFF

      • Starter signal OFF

  3. READ VALUE USING GTS (OPER PERMISSION (BATTERY))

    Tip:

    Check whether stop and start control was prohibited based on the battery conditions or other conditions.

    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).

    2. Check the following items on the GTS display.

      Table 3. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Oper Permission (Battery)

      Permission of stop and start control based on the battery conditions

      NG / OK

      OK: Stop and start control is permitted due to battery condition, or Active Test (forced permission) is performed

      -

      Table 4. Result

      Result

      Proceed to

      NG is displayed

      A

      OK is displayed

      B

    END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)

  4. READ VALUE USING GTS (STATUS OF BATTERY CHARGE CONTROL)

    Tip:

    Check whether stop and start control was prohibited based on the battery charge control mode.

    1. Start the engine and allow it to idle.

    2. Enter the following menus: Powertrain / Stop and Start / Data List / Status of Battery Charge Control.

    3. Check the following items on the GTS display.

      Table 5. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Status of Battery Charge Control

      Battery charge control status/

      Change Control Coordination Mode / Stop and Start Standalone Mode / Refresh Charge Mode / Stop and Start Restriction Mode / Temperature High / Low Mode / Abnormal Mode / Battery Condition Judgment Mode / Low Temperature Mode

      -

      -

      Table 6. Result

      Result

      Proceed to

      "Refresh Charge Mode", "Battery Condition Judgment Mode" or "Abnormal Mode" is not displayed

      A

      "Refresh Charge Mode" is displayed

      B

      "Battery Condition Judgment Mode" is displayed

      C

      "Abnormal Mode" is displayed

      D

      Tip:

      If "Refresh Charge Mode" is displayed, leave the vehicle idling for 30 to 60 minutes.

    END (STOP AND START CONTROL PROHIBITED IN REFRESH CHARGE MODE)

    END (STOP AND START CONTROL PROHIBITED IN BATTERY CONDITION JUDGMENT MODE)

    GO TO CHARGING SYSTEM

  5. READ VALUE USING GTS (OPER PERMISSION (START MIN VOLT 1, 2, 3, 4))

    Tip:

    Check whether stop and start control was prohibited based on the minimum starting voltage of the battery condition.

    1. Enter the following menus: Powertrain / Stop and Start / Data List.

    2. Check the following items on the GTS display.

      Table 7. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Oper Permission (Start Min Volt 1)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Battery temperature is 0°C (32°F) or less and the minimum voltage at starter ON is the threshold value or higher

      If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

      Oper Permission (Start Min Volt 2)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage at starter ON is the threshold value or higher

      If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

      Oper Permission (Start Min Volt 3)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Battery temperature is 0°C (32°F) or less and the minimum voltage right after engine cranking is the threshold value or higher

      If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

      Oper Permission (Start Min Volt 4)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage right after engine cranking is the threshold value or higher

      If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

      Table 8. Result

      Result

      Proceed to

      OK is displayed for 2 or more items

      A

      OK is displayed for 1 item or none

      B

      1. The Data List item "Oper Permission (Start Min Volt 1, 2, 3, 4)" is judged OK or NG according to the values of the following Data List items.

        Table 9. Stop and Start System

        GTS Display

        Measurement Item/Range

        Normal Condition

        Diagnostic Note

        Battery Temp (Start)

        Battery temperature at engine start/

        Min.: -40°C (-40°F), Max.: 100°C (212°F)

        Same as temperature around battery at engine start (after engine start)

        -

        Ambient Temp Sensor

        Ambient temperature/

        Min.: -80.0°C (-112.0°F), Max.: 79.9°C (175.8°F)

        Close to ambient temperature

        -

        Min Voltage(Cranking)

        Minimum battery voltage while engine cranking (incurrent trip)/

        Min.: 0.00 V, Max.: 327.67 V

        6 to 11 V

        Lowest battery voltage measured in a 5 second period after the starter starts operating.

        Min Volt(After Cranking)

        Minimum battery voltage just after engine cranking/

        Min.: 0.00 V, Max.: 327.67 V

        6 to 11 V

        Minimum battery voltage while starter driving

        Permission Criteria

        GTS Display

        Starting Battery Voltage

        Battery Temperature*1

        Oper Permission (Start Min Volt 1)*2

        6.6 V or higher

        0°C (32°F) or less

        Oper Permission (Start Min Volt 2)*2

        6.6 V or higher

        Higher than 0°C (32°F)

        Oper Permission (Start Min Volt 3)*3

        6.6 V or higher

        0°C (32°F) or less

        Oper Permission (Start Min Volt 4)*3

        6.6 V or higher

        Higher than 0°C (32°F)

        • *1: Read the Data List items "Battery Temp (Start)" and "Ambient Temp Sensor" when checking the battery temperature.

        • *2: Operation is permitted when the minimum voltage is 6.6 V or more when 0.0049 seconds have elapsed after cranking the engine.

        • *3: Operation is permitted when the minimum voltage is 6.6 V or more right after cranking the engine.

    END (CHECK BATTERY CONDITION AND RECHARGE OR REPLACE BATTERY)

  6. READ VALUE USING GTS (OPER PERMISSION (BATTERY CURRENT))

    Tip:

    Check whether the stop and start control was prohibited based on the battery discharge current battery condition.

    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery Current).

    2. Check the following items on the GTS display.

      Table 10. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Oper Permission (Battery Current)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Battery discharge current is -125 A or less

      Engine stop and start ECU calculated value

      Table 11. Result

      Result

      Proceed to

      OK is displayed

      A

      NG is displayed

      B

      1. The Data List item "Oper Permission (Battery Current)" is judged OK or NG according to the values of the following Data List items.

        Table 12. Stop and Start System

        GTS Display

        Measurement Item/Range

        Normal Condition

        Diagnostic Note

        Battery Current

        Battery current/

        Min.: -125.00 A, Max.: 124.99 A

        -

        -

        Permission Criteria

        GTS Display

        Battery Current

        Oper Permission (Battery Current)

        -125 A or less

    END (REDUCE ELECTRICAL LOAD)

  7. READ VALUE USING GTS (OPER PERMISSION (INTEGRATED CURRENT))

    Tip:

    Check whether the stop and start control was prohibited based on the integrated current value battery condition.

    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Integrated Current).

    2. Check the following items on the GTS display.

      Table 13. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Oper Permission (Integrated Current)

      Permission of stop and start control based on the integrated current value conditions/

      NG / OK

      OK: Integrated current value more than specified

      The condition is judged based on the integrated current value. The status depends on the value of "Integrated Current", and OK/NG threshold differs according to the battery temperature.

      Table 14. Result

      Result

      Proceed to

      OK is displayed

      A

      NG is displayed

      B

    READ VALUE USING GTS (INTEGRATED CURRENT)Click here

  8. READ VALUE USING GTS (STATE OF BBC AND BBC CHECK RESULT)

    Tip:

    Check the operation of the backup boost converter.

    1. Enter the following menus: Powertrain / Stop and Start / Data List / State of BBC and BBC Check Result.

    2. Check the following items on the GTS display.

      Table 15. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      State of BBC

      Backup boost converter status/

      Cycle Err / Overvol / Overload / Normal / Low Vol / Duty Err / S&S Sensor Electric Supply Low / S&S CPU Malfunction / BBC Overcurrent / S&S Starter Overcurrent / S&S Reduced Voltage Reset

      Normal: Backup boost converter operating normally

      • Cycle Err:

        • Abnormal output voltage cycle is detected

      • Overvol:

        • When the ignition switch is ON:

          1. Overvoltage is detected at the control IC power source within the backup boost converter

          2. Overheating is detected at the control IC power source within the backup boost converter

        • When boosting:

          1. Error is detected in the feedback circuit in the backup boost converter

          2. Too high or low output voltage

      • Overload:

        • Overcurrent is detected.

      • Low Vol:

        • A decrease in the voltage of the control IC power source within the backup boost converter is detected when ignition switch is turned to ON.

      • Duty Err:

        • Abnormal duty ratio is detected

      BBC Check Result

      Backup boost converter check result/

      Normal / Abnormal

      -

      -

      Table 16. Result

      Result

      Proceed to

      Normal is displayed

      A

      Normal is not displayed

      B

    GO TO BACKUP BOOST CONVERTER CIRCUIT

  9. READ VALUE USING GTS (OPER PROHIBITION (JUMP START))

    Tip:

    Check whether stop and start control was prohibited based on the jump start battery condition.

    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Jump Start).

    2. Check the following items on the GTS display.

      Table 17. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Oper Prohibition (Jump Start)

      Prohibition of stop and start control based on the jump start conditions/

      Permit / Prohibit

      Prohibit: Engine started with the engine hood open and the ignition switch turned to START

      When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.

      Table 18. Result

      Result

      Proceed to

      Permit is displayed

      A

      Prohibit is displayed

      B

      1. The Data List item "Oper Permission (Jump Start)" is judged Permit or Prohibit according to the values of the following Data List items.

        Table 19. Stop and Start System

        GTS Display

        Measurement Item/Range

        Normal Condition

        Diagnostic Note

        Hood Courtesy Switch

        Hood courtesy switch signal/

        ON / OFF

        ON: Engine hood closed

        OFF: Engine hood opened

        -

        Oper Permission (Engine Hood Closed)

        Permission of stop and start control based on the engine hood open/close conditions/

        NG / OK

        OK: Engine hood closed

        -

        Permission Criteria

        GTS Display

        Conditions

        Oper Prohibition (Jump Start)

        ON (Engine hood closed) is displayed for Hood Courtesy Switch

        OK (Engine Hood Closed) is displayed for Oper Permission (Engine Hood Closed)

    READ VALUE USING GTS (HOOD COURTESY SWITCH)Click here

  10. READ VALUE USING GTS (OPER PROHIBITION (MANUAL START))

    Tip:

    Check whether the stop and start control was prohibited based on the manual start battery condition.

    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Manual Start).

    2. Check the following items on the GTS display.

      Table 20. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Oper Prohibition (Manual Start)

      Prohibition of stop and start control based on the manual start conditions/

      Permit / Prohibit

      Prohibit: During manual start

      When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off. Conditions for Manual Start:

      • Clutch start switch OFF or vehicle speed signal input

      • Neutral position sensor (neutral position switch) OFF

      • Starter signal OFF

      Table 21. Result

      Result

      Proceed to

      Permit is displayed

      A

      Prohibit is displayed

      B

    END (STOP AND START CONTROL PROHIBITED DUE TO MANUAL START OPERATION)

  11. READ VALUE USING GTS (OPER PERMISSION (BATTERY))

    Tip:

    Check whether the stop and start control was prohibited based on the battery temperature battery condition.

    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).

    2. Check the following items on the GTS display.

      Table 22. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Oper Permission (Battery)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed

      -

      Table 23. Result

      Result

      Proceed to

      NG is displayed

      A

      OK is displayed

      B

      1. The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.

        Table 24. Stop and Start System

        GTS Display

        Measurement Item/Range

        Normal Condition

        Diagnostic Note

        Battery Temp (Start)

        Battery temperature at engine start/

        Min.: -40°C (-40°F), Max.: 100°C (212°F)

        Same as temperature around battery at engine start (after engine start)

        -

        Ambient Temp Sensor

        Ambient temperature/

        Min.: -80.0°C (-112.0°F), Max.: 79.9°C (1175.8°F)

        Close to ambient temperature

        -

        Permission Criteria

        GTS Display

        Conditions

        Oper Permission (Battery Current)

        Current battery temperature is between -10°C (14°F) and 70°C (158°F)

        Tip:

        *: Read the Data List items "Battery Temp (Start)" and "Ambient Temp Sensor" when checking the battery temperature.

    END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)

  12. READ VALUE USING GTS (BATTERY TEMP (START))

    Tip:

    Check the battery temperature.

    1. Enter the following menus: Powertrain / Stop and Start / Data List.

    2. Check the following items on the GTS display.

      Table 25. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Battery Temp (Start)

      Battery temperature at engine start/

      Min.: -40°C (-40°F), Max.: 100°C (212°F)

      Same as temperature around battery at engine start (after engine start)

      -

      Ambient Temp Sensor

      Ambient temperature/

      Min.: -80.0°C (-112.0°F), Max.: 79.9°C (175.8°F)

      Close to ambient temperature

      -

      Table 26. Result

      Result

      Proceed to

      Battery temperature is as specified

      A

      Battery temperature is not as specified

      B

      Tip:

      If the battery temperature is not as specified, leave the battery under room temperature conditions until its temperature becomes as specified.

    END (STOP AND START CONTROL PROHIBITED DUE TO ABNORMAL BATTERY TEMPERATURE)

  13. READ VALUE USING GTS (OPER PERMISSION (BATTERY))

    Tip:

    Check whether stop and start control was prohibited based on the alternator status battery condition.

    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).

    2. Check the following items on the GTS display.

      Table 27. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Oper Permission (Battery)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed

      -

      Table 28. Result

      Result

      Proceed to

      NG is displayed

      A

      OK is displayed

      B

      1. The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.

        Table 29. Stop and Start System

        GTS Display

        Measurement Item/Range

        Normal Condition

        Diagnostic Note

        Alternator Status

        Alternator power generation status/

        Normal / Abnormal

        Normal: Alternator operation normal

        -

        Permission Criteria

        GTS Display

        Conditions

        Oper Permission (Battery)

        Normal is displayed for Alternator Status (Alternator is generating power)

        Charge indicator light is off when the engine is running (Alternator is generating power)

    END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)

  14. READ VALUE USING GTS (ALTERNATOR STATUS)

    Tip:

    Check the power generation status of the alternator.

    1. Start the engine and allow it to idle.

    2. Enter the following menus: Powertrain / Stop and Start / Data List / Alternator Status.

    3. Check the following items on the GTS display.

      Table 30. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Alternator Status

      Alternator power generation status/

      Normal / Abnormal

      Normal: Alternator operation normal

      -

      Table 31. Result

      Result

      Proceed to

      Normal is displayed

      A

      Abnormal is displayed

      B

    GO TO CHARGING SYSTEM

  15. READ VALUE USING GTS (OPER PERMISSION (BATTERY))

    Tip:

    Check whether stop and start control was prohibited based on the idling stop rate battery condition.

    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).

    2. Check the following items on the GTS display.

      Table 32. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Oper Permission (Battery)

      Permission of stop and start control based on the battery conditions/

      NG / OK

      OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed

      -

      Table 33. Result

      Result

      Proceed to

      NG is displayed

      A

      OK is displayed

      B

      1. The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.

        Table 34. Stop and Start System

        GTS Display

        Measurement Item/Range

        Normal Condition

        Diagnostic Note

        Idling Stop Rate

        Rate of the idling stop time to the entire ignition switch ON time/

        Min.: 0%, Max.: 100%

        -

        -

        Permission Criteria

        GTS Display

        Idling Stop Rate

        Oper Permission (Battery)

        39% or less

        Tip:

        When the idling stop rate exceeds 40%, stop and start control is permitted when the rate drops to 37% or less.

    END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)

  16. READ VALUE USING GTS (IDLING STOP RATE)

    Tip:

    Check the idling stop rate.

    1. Enter the following menus: Powertrain / Stop and Start / Data List / Idling Stop Rate.

    2. Check the following items on the GTS display.

      Table 35. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Idling Stop Rate

      Rate of the idling stop time to the entire ignition switch ON time/

      Min.: 0%, Max.: 100%

      -

      -

      Table 36. Result

      Result

      Proceed to

      40% or higher

      A

      39% or less

      B

      Tip:

      When the idling stop rate exceeds 40%, turn the ignition switch off and then start the engine again. If NG is still displayed for the Data List item "Oper Permission (Battery)", the battery may be discharged or deteriorated. Check the battery condition and recharge or replace the battery.

    END (STOP AND START CONTROL PROHIBITED DUE TO HIGH IDLING STOP RATE (40% OR MORE))

    END (CHECK BATTERY CONDITION AND RECHARGE OR REPLACE BATTERY)

  17. READ VALUE USING GTS (HOOD COURTESY SWITCH)

    Tip:

    Check the engine hood courtesy switch (hood lock assembly).

    1. Enter the following menus: Powertrain / Stop and Start / Data List / Hood Courtesy Switch.

    2. Check the following items on the GTS display.

      Table 37. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Hood Courtesy Switch

      Hood courtesy switch signal/

      ON / OFF

      ON: Engine hood closed

      OFF: Engine hood opened

      -

      Tip:

      When the result is OK, the engine may have been started with the engine hood open to perform a jump start. Close the engine hood and start the engine again.

    END (STOP AND START CONTROL PROHIBITED DUE TO ENGINE START WITH ENGINE HOOD OPEN)

    GO TO ENGINE HOOD COURTESY SWITCH CIRCUIT

  18. READ VALUE USING GTS (INTEGRATED CURRENT)

    Tip:

    Judge the battery condition based on the integrated current value.

    1. Start the engine and allow it to idle.

    2. Enter the following menus: Powertrain / Stop and Start / Data List / Integrated Current.

    3. Check the following items on the GTS display.

      Table 38. Stop and Start System

      GTS Display

      Measurement Item/Range

      Normal Condition

      Diagnostic Note

      Integrated Current

      Battery integrated current/

      Min.: -268434.45 A-sec, Max.: 268435.45 A-sec

      Differs according to the vehicle condition (charge / discharge conditions)

      -

      1. Judge whether the Data List item "Integrated Current" is OK or NG according to the following table.

        Table 39. Stop and Start System

        GTS Display

        Measurement Item/Range

        Normal Condition

        Diagnostic Note

        Battery Temp (Start)

        Battery temperature at engine start/

        Min.: -40°C (-40°F), Max.: 100°C (212°F)

        Same as temperature around battery at engine start (after engine start)

        -

        Idle

        Battery temperature at engine start/

        ON / OFF

        ON: Accelerator pedal fully released

        OFF: Accelerator pedal depressed

        This is sent from the ECM.

        Battery Current

        Battery current/

        Min.: -125.00 A, Max.: 124.99 A

        -

        -

        Ambient Temp Sensor

        Ambient temperature/

        Min.: -80.0°C (-112.0°F), Max.: 79.9°C (175.8°F)

        Close to ambient air temperature

        -

        Integrated Current

        Battery integrated current/

        Min.: -268434.45 A-sec, Max.: 268435.45 A-sec

        Differs according to the vehicle condition (charge/discharge conditions)

        -

        Standard Integrated Current Value

        Battery Temperature

        GTS Display

        Integrated Current

        Proceed to

        -1°C (30.2°F) or higher, or 65°C (149°F) or less

        Integrated Current

        Below -5299 A-sec

        A

        -1°C (30.2°F) or higher, or 65°C (149°F) or less

        Below 0 A-sec

        A

        Below -1°C (30.2°F) or -15°C (5°F) or higher, or 65°C (149°F) or higher, or 75°C (167°F) or less

        Below -15°C (5°F) or higher than 75°C (167°F)

        -

        B

        Cause and Action to be Taken

        Result

        Cause

        Action to be Taken

        A

        Integrated current value is limited for the stop and start control due to discharge or deterioration of the battery

        Check the battery condition and recharge or replace the battery

        B

        Integrated current value is limited for stop and start control due to battery temperature (too high/low)

        Leave the battery under room temperature conditions until its temperature becomes as specified. Then check the battery condition and recharge or replace the battery.

        • After recharging the battery, initialize the integrated current value* and drive the vehicle until stop and start control operation is permitted (approximately 15 to 40 minutes).

          *: Disconnect the cables from the battery, wait for 30 seconds or more and then reconnect the cables.

        • When the battery sensor current value is normal, recharge or replace the battery.

    END (RECHARGE OR REPLACE BATTERY)