CRANKSHAFT POSITION SENSOR INSPECTION
PROCEDURE
INSPECT CRANK POSITION SENSOR
-
*a
Component without harness connected:
(Crank Position Sensor)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
Cold
1630 to 2740 Ω
Hot
2065 to 3225 Ω
Tip:"Cold" and "Hot" mean the temperature of the coils themselves. "Cold" is from -10 to 50°C (14 to 122 °F) and "Hot" is from 50 to 100°C (122 to 212°F).
If the resistance is not as specified, replace the sensor.
-