INTEGRATION RELAY INSPECTION

PROCEDURE

  1. INSPECT NO. 1 INTEGRATION RELAY

    A354291C01

    *1

    No. 1 Integration Relay

    -

    -

    1. IG2 Relay:

      1. A196170C02

        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance

        Tester Connection

        Condition

        Specified Condition

        1K-1 - 1I-4

        Battery voltage not applied between terminals 1I-3 and 1I-2

        10 kΩ or higher

        1K-1 - 1I-4

        Battery voltage applied between terminals 1I-3 and 1I-2

        Below 1 Ω

        1I-1 - 1I-4

        If the result is not as specified, replace the No. 1 integration relay.

    2. HORN Relay:

      1. A196170C02

        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance

        Tester Connection

        Condition

        Specified Condition

        1K-1 - 1I-8

        Battery voltage not applied between terminals 1I-7 and 1I-6

        10 kΩ or higher

        1K-1 - 1I-8

        Battery voltage applied between terminals 1I-7 and 1I-6

        Below 1 Ω

        1I-5 - 1I-8

        If the result is not as specified, replace the No. 1 integration relay.

    3. FUEL PUMP Relay:

      1. A196170C02

        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance

        Tester Connection

        Condition

        Specified Condition

        1K-1 - 1J-4

        Battery voltage not applied between terminals 1J-3 and 1J-2

        10 kΩ or higher

        1K-1 - 1J-4

        Battery voltage applied between terminals 1J-3 and 1J-2

        Below 1 Ω

        1J-1 - 1J-4

        If the result is not as specified, replace the No. 1 integration relay.

    4. EDU Relay:

      1. A196170C02

        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance

        Tester Connection

        Condition

        Specified Condition

        1J-5 - 1J-8

        Battery voltage not applied between terminals 1J-7 and 1J-6

        10 kΩ or higher

        Battery voltage applied between terminals 1J-7 and 1J-6

        Below 1 Ω

        If the result is not as specified, replace the No. 1 integration relay.