CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM, Diagnostic DTC:P282B

DTC Code DTC Name
P282B Pressure Control Solenoid "K" Electrical (Shift Solenoid Valve SLS)

DESCRIPTION

According to current control by the ECM, the shift solenoid valve SLS controls secondary pulley pressure and belt clamping pressure in accordance with the input shaft torque.

C267073C01

*1

Spool Valve

*2

Sleeve

*3

Solenoid Coil

-

-

*a

Hydraulic Pressure

*b

Current Flow to Solenoid

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

MIL

Memory

P282B

Pressure Control Solenoid "K" Electrical (Shift Solenoid Valve SLS)

1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other

  1. The vehicle is being driven.

  2. An open or short circuit in the shift solenoid valve SLS circuit is detected.

  3. 1 second or more

  4. 1-trip detection logic

  • Harness or connector

  • Continuously variable transaxle assembly (Shift solenoid valve SLS)

  • ECM

Comes on

DTC stored

MONITOR DESCRIPTION

This DTC indicates an open or short circuit in the shift solenoid valve SLS circuit. If there is an open or short circuit in the shift solenoid valve SLS circuit, the ECM detects the problem, illuminates the MIL and stores this DTC.

WIRING DIAGRAM

C262369E76

CAUTION / NOTICE / HINT

Note:
  • Perform initialization when parts related to the continuously variable transaxle are replaced.

    Click here

  • Check that no DTCs are stored after performing initialization.

    Click here

PROCEDURE

  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLS)

    1. C298188C12

      *a

      Component without harness connected

      (Transmission Wire)

      Disconnect the transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      2 (SLS+) - 8 (SLS-)

      20°C (68°F)

      5.0 to 5.6 Ω

      2 (SLS+) - Body ground and other terminals

      Always

      10 kΩ or higher

      8 (SLS-) - Body ground and other terminals

      Always

      10 kΩ or higher

    Result

    Proceed to

    OK

    NG

    NG

    REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLYClick here

    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

    1. C326700C01

      *a

      Front view of wire harness connector

      (to ECM)

      Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      B93-45 (SLS+) - B93-44 (SLS-)

      20°C (68°F)

      5.0 to 5.6 Ω

      B93-45 (SLS+) - Body ground and other terminals

      Always

      10 kΩ or higher

      B93-44 (SLS-) - Body ground and other terminals

      Always

      10 kΩ or higher

    Result

    Proceed to

    OK

    NG

    NG

    REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM)

    OK
  3. REPLACE ECM

    1. Replace the ECM.

      Click here

    Result

    Proceed to

    NEXT

    NEXT

    PERFORM INITIALIZATION

  4. REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY

    1. Replace the continuously variable transaxle assembly.

      Click here

    Result

    Proceed to

    NEXT

    NEXT

    PERFORM INITIALIZATION