CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM, Diagnostic DTC:P282B
| DTC Code | DTC Name |
|---|---|
| P282B | Pressure Control Solenoid "K" Electrical (Shift Solenoid Valve SLS) |
DESCRIPTION
According to current control by the ECM, the shift solenoid valve SLS controls secondary pulley pressure and belt clamping pressure in accordance with the input shaft torque.
*1 |
Spool Valve |
*2 |
Sleeve |
*3 |
Solenoid Coil |
- |
- |
*a |
Hydraulic Pressure |
*b |
Current Flow to Solenoid |
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
MIL |
Memory |
|---|---|---|---|---|---|
P282B |
Pressure Control Solenoid "K" Electrical (Shift Solenoid Valve SLS) |
1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
|
|
Comes on |
DTC stored |
MONITOR DESCRIPTION
This DTC indicates an open or short circuit in the shift solenoid valve SLS circuit. If there is an open or short circuit in the shift solenoid valve SLS circuit, the ECM detects the problem, illuminates the MIL and stores this DTC.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Perform initialization when parts related to the continuously variable transaxle are replaced.
Check that no DTCs are stored after performing initialization.
PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLS)
-
*a
Component without harness connected
(Transmission Wire)
Disconnect the transmission wire connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
2 (SLS+) - 8 (SLS-)
20°C (68°F)
5.0 to 5.6 Ω
2 (SLS+) - Body ground and other terminals
Always
10 kΩ or higher
8 (SLS-) - Body ground and other terminals
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLYClick here
-
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
-
*a
Front view of wire harness connector
(to ECM)
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
B93-45 (SLS+) - B93-44 (SLS-)
20°C (68°F)
5.0 to 5.6 Ω
B93-45 (SLS+) - Body ground and other terminals
Always
10 kΩ or higher
B93-44 (SLS-) - Body ground and other terminals
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM)
-
REPLACE ECM
Replace the ECM.
Result
Proceed to
NEXT
REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
Replace the continuously variable transaxle assembly.
Result
Proceed to
NEXT