FRONT BLOWER MOTOR INSPECTION

PROCEDURE

  1. INSPECT BLOWER WITH FAN MOTOR SUB-ASSEMBLY (for Manual Air Conditioning System)

    1. Disconnect the connector from the blower motor.

    2. E145300E17

      Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 1, and check that the motor operates.

      OK

      The blower motor operates smoothly.

      If the result is not as specified, replace the blower with fan motor sub-assembly.