DESCRIPTION
The main body ECU (multiplex network body ECU) controls the operation of the following lights:
Map light assembly
No. 1 room light assembly
Tech Tips
The light cut relay supplies power to the lights not controlled by the illuminated entry system. If all of the lights that use power from the light cut relay do not turn on, check the light cut relay circuit first Click here.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Note
Inspect fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
PERFORM ACTIVE TEST USING GTS
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Active Test.
Check that the lights operate.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Illuminated Entry System | Personal light and No. 1 room light assembly | ON/OFF | Interior light door switch on and all doors closed |
| OK |
|---|
| Each light fades in. |
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| NG |
|
INSPECT MAP LIGHT ASSEMBLY
Remove the map light assembly Click here.
Inspect the map light assembly Click here.
| OK |
|---|
| Map light assembly is normal. |
| NG |
|
REPLACE MAP LIGHT ASSEMBLY Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (MAP LIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Disconnect the 2A instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
*1: for LHD
*2: for RHD
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Remove the instrument panel junction block assembly Click here.
| *a | Component without harness connected (Instrument Panel Junction Block Assembly) |
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly Click here.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| OK |
|
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) Click here |
| NG |
|
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY Click here |