PRE-CRASH SAFETY SYSTEM FREEZE FRAME DATA
CHECK FREEZE FRAME DATA
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Pre-Crash 2 / Trouble Codes.
Body Electrical > Pre-Crash 2 > Trouble Codes
According to the GTS display, select a DTC that stored freeze frame data.
Read the freeze frame data recorded when the DTC was stored.
Body Electrical > Pre-Crash 2
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Turn Light RH
Turn signal switch (right) status
ON or OFF
ON: Turn signal switch (right) on
OFF: Turn signal switch (right) off
-
Turn Light LH
Turn signal switch (left) status
ON or OFF
ON: Turn signal switch (left) on
OFF: Turn signal switch (left) off
-
PCS OFF Switch
Pre-crash safety system switch status
ON or OFF
ON: Pre-crash safety system function disabled due to switch operation
OFF: Pre-crash safety system function enabled due to switch operation
-
Pre-Crash Safety Warning Buz
Pre-crash safety system warning buzzer
Valid or Inval
Valid: Pre-crash safety system warning buzzer operation possible
Inval: Pre-crash safety system warning buzzer operation not possible
-
Pre-Crash Brake
Pre-crash brake function
Valid or Inval
Valid: Pre-crash brake operation possible
Inval: Pre-crash brake operation not possible
-
PBA Start
Pre-crash brake assist activation signal
OFF, Standby, Assist Lv1 or Assist Lv2
OFF: Pre-crash brake assist not activated
Standby: Pre-crash brake assist standby
Assist Lv1: Pre-crash brake assist activated
Assist Lv2: Pre-crash brake assist activated
Signal status changes when the pre-crash brake assist is activated before a crash (Pre-crash brake will activate only in situations where the driver depresses the brake pedal)
Warning Brake
-
-
-
Not applicable to the vehicle
Brake Assist Standby
Supplemental brake pressure signal
ON or OFF
ON: Supplemental brake pressure being provided
OFF: Supplemental brake pressure not being provided
-
Pre-Crash Brake Control
Pre-crash brake operational status
ON or OFF
ON: Pre-crash brake operating
OFF: Pre-crash brake not operating
-
AVS Start
-
-
-
Not applicable to the vehicle
VGRS Start
-
-
-
Not applicable to the vehicle
PBA Control
Pre-crash brake assist operational status
Valid or Invalid
Valid: Pre-crash brake assist control operation possible
Invalid: Pre-crash brake assist control operation not possible
-
Pre-Crash Safety Brake Ind
Pre-crash safety system alarm warning message status
ON or OFF
ON: Pre-crash safety system "BRAKE!" alert on
OFF: Pre-crash safety system "BRAKE!" alert off
"BRAKE!" is displayed
PCS Crash Alarm Buzzer
Skid control buzzer status
ON or OFF
ON: Skid control buzzer sounds
OFF: Skid control buzzer does not sound
-
Front Radar-Low Voltage History
Millimeter wave radar sensor assembly low voltage history
ON or OFF
ON: History of low voltage
OFF: No history of low voltage
-
Front Radar-Incorrect Axial Gap (Vertical) History
Millimeter wave radar sensor assembly vertical misalignment history
ON or OFF
ON: History of vertical misalignment
OFF: No history of vertical misalignment
-
Front Radar-Incorrect Axial Gap (Horizontal) History
Millimeter wave radar sensor assembly horizontal misalignment history
ON or OFF
ON: History of horizontal misalignment
OFF: No history of horizontal misalignment
-
Front Recognition Camera-Malfunction History
Forward recognition camera malfunction history (abnormal temperature, low voltage, DTC stored, etc.)
ON or OFF
ON: History of malfunction
OFF: No history of malfunction
-
Control Mode
ECU control mode status
Normal or Check Mode
Normal: Normal operation
Check Mode: Operating in Control Mode
-
PCS Operation State Retention Setting
Displays the setting of the PCS Operation State Retention Setting customize setting
ON or OFF
ON: PCS Operation State Retention Setting customize setting is set to ON
OFF: PCS Operation State Retention Setting customize setting is set to OFF
-
PCS Alarm Activation Distance Retention Setting 1
Displays the setting of the PCS Alarm Activation Distance Retention Setting 1 customize setting
ON or OFF
ON: PCS Alarm Activation Distance Retention Setting 1 customize setting is set to ON
OFF: PCS Alarm Activation Distance Retention Setting 1 customize setting is set to OFF
-
PCS Alarm Activation Distance Retention Setting 2
Displays the setting of the PCS Alarm Activation Distance Retention Setting 2 customize setting
ON or OFF
ON: PCS Alarm Activation Distance Retention Setting 2 customize setting is set to ON
OFF: PCS Alarm Activation Distance Retention Setting 2 customize setting is set to OFF
-
PCS Alarm Activation Distance Retention Setting 3
Displays the setting of the PCS Alarm Activation Distance Retention Setting 3 customize setting
ON or OFF
ON: PCS Alarm Activation Distance Retention Setting 3 customize setting is set to ON
OFF: PCS Alarm Activation Distance Retention Setting 3 customize setting is set to OFF
-