FUEL SUPPLY PUMP(w/o Glow Plug Controller) INSPECTION
PROCEDURE
INSPECT SUPPLY PUMP ASSEMBLY
*a
Component without harness connected
(Suction Control Valve)
*b
Component without harness connected
(Fuel Temperature Sensor)
Inspect the resistance of the suction control valve.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Terminals
Condition
Resistance
1 - 2
20°C (68°F)
2.60 to 3.15 Ω
If the result is not as specified, replace the supply pump assembly.
Inspect the resistance of the fuel temperature sensor.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Terminals
Condition
Resistance
1 - 2
-20°C (-4°F)
13.92 to 17.01 kΩ
1 - 2
0°C (32°F)
5.31 to 6.49 kΩ
1 - 2
20 °C (68°F)
2.25 to 2.75 kΩ
1 - 2
40°C (104°F)
1.06 to 1.29 kΩ
1 - 2
60°C (140°F)
0.54 to 0.66 kΩ
1 - 2
80 °C (176°F)
0.29 to 0.36 kΩ
1 - 2
100°C (212°F)
0.17 to 0.20 kΩ
If the result is not as specified, replace the supply pump assembly.