RELAY ON-VEHICLE INSPECTION
PROCEDURE
INSPECT STARTER NO. 1 RELAY (ST NO. 1)
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 - 5
Battery voltage not applied to terminals 1 and 2
10 kΩ or higher
Battery voltage applied to terminals 1 and 2
Below 1 Ω
If the result is not as specified, replace the starter No. 1 relay.
-
INSPECT STARTER NO. 2 RALAY (ST NO. 2)
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 - 5
Battery voltage not applied to terminals 1 and 2
10 kΩ or higher
Battery voltage applied to terminals 1 and 2
Below 1 Ω
If the result is not as specified, replace the starter No. 2 relay.
-