СИСТЕМА ЗАПУСКА И ОСТАНОВА (для моделей с 2AR-FE) Neutral Position Switch Circuit

DESCRIPTION

The engine stop and start ECU uses the park/neutral position switch assembly installed to the continuously variable transaxle assembly to detect when the shift lever is in P or N.

WIRING DIAGRAM

Refer to DTC P085012.

Click here

CAUTION / NOTICE / HINT

Note


  • When replacing the engine stop and start ECU with a new one, make sure to download the previous status (number of starter operations) of the old engine stop and start ECU. After replacing the engine stop and start ECU, turn the engine switch on (IG) and wait 20 seconds, then confirm that "OK" is displayed for the Data List item [Stop&Start Operating Permission (Discharged Oil Pump Air)]. Then upload the previous status (number of starter operations) to the engine stop and start ECU.

    Click here

  • After replacing the engine stop and start ECU or air conditioning amplifier assembly, reset and perform learning of the air conditioning information in the engine stop and start ECU.

    Click here

  • After replacing the engine stop and start ECU or airbag ECU assembly, clear and calibrate the deceleration sensor zero point in the engine stop and start ECU.

    Click here

  • After replacing the engine stop and start ECU, perform learning of the external backup boost converter (eco run vehicle converter assembly).

    Click here

PROCEDURE


  1. READ VALUE USING GTS (NEUTRAL SWITCH)


    1. Connect the GTS to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Stop and Start / Data List / Neutral Switch.


      Powertrain > Stop and Start > Data List
      Tester Display
      Neutral Switch
    5. In accordance with the display on the GTS, read the Data List.

      OK
      GTS Display Condition Normal Condition
      Neutral Switch Shift lever in P or N ON
      Shift lever not in P or N OFF
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY


    1. Inspect the park/neutral position switch assembly.

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - PARK/NEUTRAL POSITION SWITCH ASSEMBLY)


    1. Disconnect the engine stop and start ECU connector.

    2. Disconnect the park/neutral position switch assembly connector.

    3. Disconnect the ECM connector.

    4. Disconnect the certification ECU (smart key ECU Assembly) connector.

    5. Remove the ST NO. 1 relay from the No. 1 engine room relay block.

    6. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A60-21 (STA) - D5-9 (L) Always Below 1 Ω
      A60-17 (CLL) - D5-4 (B) Always Below 1 Ω
      A60-21 (STA) or D5-9 (L) - Body ground and other terminals Always 10 kΩ or higher
      A60-17 (CLL) or D5-4 (B) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG