GENERATOR(for 90A Type) REMOVAL

PROCEDURE

  1. PRECAUTION

    Note:

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notice before proceeding with work.

    Click hereClick here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click hereClick here

  3. REMOVE NO. 2 CYLINDER HEAD COVER

  4. REMOVE V-RIBBED BELT

  5. REMOVE GENERATOR ASSEMBLY

    1. A258120

      Remove the terminal cap.

    2. Remove the nut and disconnect the wire harness from terminal B.

    3. Disconnect the connector and harness clamp.

    4. A282535

      Remove the 2 bolts and adjusting bar.

    5. A282536

      Remove the bolt and generator assembly.

    6. A207654

      Remove the bolt and wire harness clamp bracket.