1GD-FTV EMISSION CONTROL SERVICE DATA

NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω

1 - Body ground

2 - Body ground

20°C (68°F) 1 MΩ or higher
EXHAUST GAS TEMPERATURE SENSOR
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 89.3 to 159.8 kΩ
EXHAUST FUEL ADDITION INJECTOR
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 7.1 to 7.9 Ω