AIR CONDITIONING SYSTEM Back-up Power Source Circuit
| DTC Code | DTC Name |
|---|---|
| Back-up Power Source Circuit |
DESCRIPTION
The back-up power source circuit for the air conditioning amplifier assembly is shown below. Power is supplied even after the engine switch is turned off and is used for diagnostic trouble code memory, etc.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY)
-
*a
Rear view of wire harness connector
(to Air Conditioning Amplifier Assembly)
Disconnect the G13 amplifier connector.
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
G13-21 (B) - Body ground
Always
11 to 14 V
Result
Result
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
-