AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) PROBLEM SYMPTOMS TABLE
Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspected areas in the order they are listed. Replace parts as necessary.
Inspect the fuses and relays related to this system before inspecting the suspected areas below.
Symptom |
Suspected Area |
Link |
|---|---|---|
All functions of the A/C system do not operate |
IG power source circuit |
|
Air conditioning amplifier assembly |
||
Air flow control: No blower operation |
Blower motor circuit |
|
Air conditioning amplifier assembly |
||
Air flow control: No blower control |
Blower motor circuit |
|
Air conditioning amplifier assembly |
||
Air flow control: Insufficient air flow |
Blower motor circuit |
|
Air conditioning amplifier assembly |
||
Temperature control: Cooling effectiveness is poor |
Refrigerant shortage check using the GTS |
|
Refrigerant volume |
- |
|
Refrigerant pressure*7 |
||
Refrigerant pressure*8 |
||
Cooler expansion valve |
||
Compressor assembly with pulley*1 |
||
Compressor assembly with pulley*2 |
||
Compressor assembly with pulley*3 |
||
Compressor assembly with pulley*4 |
||
Compressor assembly with pulley*5 |
||
Air conditioning amplifier assembly |
||
Temperature control: No cool air comes out |
Refrigerant shortage check using the GTS |
|
Refrigerant volume |
- |
|
Refrigerant pressure*7 |
||
Refrigerant pressure*8 |
||
Air mix damper control cable sub-assembly |
||
Heater control switch circuit |
||
Air conditioning pressure sensor circuit |
||
Compressor solenoid circuit |
||
Evaporator temperature sensor circuit |
||
Ambient temperature sensor circuit |
||
Cooler expansion valve |
||
Air conditioning amplifier assembly |
||
ECM*1 |
||
ECM*2 |
||
ECM*3 |
||
ECM*4 |
||
ECM*5 |
||
Temperature control: No warm air comes out |
Air mix damper control cable sub-assembly |
|
Heater control switch circuit |
||
Ambient temperature sensor circuit |
||
PTC heater circuit*6 |
||
Air conditioning amplifier assembly |
||
ECM*1 |
||
ECM*2 |
||
ECM*3 |
||
ECM*4 |
||
ECM*5 |
||
Temperature control: Output air is warmer or cooler than the set temperature or response is slow |
Refrigerant shortage check using the GTS |
|
Refrigerant volume |
- |
|
Refrigerant pressure*7 |
||
Refrigerant pressure*8 |
||
Air mix damper control cable sub-assembly |
||
Compressor solenoid circuit |
||
Ambient temperature sensor circuit |
||
Heater radiator unit sub-assembly |
||
PTC heater circuit*6 |
||
Cooler expansion valve |
||
Air conditioning amplifier assembly |
||
ECM*1 |
||
ECM*2 |
||
ECM*3 |
||
ECM*4 |
||
ECM*5 |
||
Temperature control: No temperature control (only max. cool or max. warm) |
Heater control switch circuit |
|
Air mix damper control cable sub-assembly |
||
Ambient temperature sensor circuit |
||
Evaporator temperature sensor circuit |
||
Air conditioning amplifier assembly |
||
No air inlet control |
Recirculation damper servo motor circuit |
|
Air conditioning amplifier assembly |
||
No air flow mode control |
No. 1 heater control sub-assembly |
|
No. 2 heater control cable sub-assembly |
||
Quick heater assembly does not operate*6 |
PTC heater circuit |
|
Air conditioning amplifier assembly |
||
Diagnostic Trouble Codes (DTCs) are not recorded. Set mode is cleared when the ignition switch is turned off |
Air conditioning amplifier assembly |
*1: for 1NR-FE
*2: for 1ZR-FAE
*3: for 2ZR-FE
*4: for 1ZR-FE
*5: for 1ND-TV
*6: w/ PTC Heater
*7: for HFC-134a (R134a)
*8: for HFO-1234yf (R1234yf)