ECM INSTALLATION

PROCEDURE

  1. INSTALL NO. 2 ECM BRACKET

    1. Install the No. 2 ECM bracket to the ECM with the 2 screws.

      3.0 N*m

      31 kgf*cm

      27 in.*lbf

  2. INSTALL ECM BRACKET

    1. Install the No. 1 ECM bracket to the ECM with the 2 screws.

      3.0 N*m

      31 kgf*cm

      27 in.*lbf

  3. INSTALL ECM

    1. Install the ECM with the 2 bolts.

      12.5 N*m

      127 kgf*cm

      9 ft.*lbf

      Note:

      If a component has been dropped or subjected to a strong impact, replace it.

    2. A287749

      Connect the 2 ECM connectors and lower the 2 levers.

      Note:
      • When connecting the connectors, make sure that dirt, water or other foreign matter does not contact the connecting parts of the connectors.

      • Make sure that the 2 levers are locked securely.

    3. Install the wire harness clamp.

  4. INSTALL NO. 1 AIR CLEANER INLET

    1. A287747

      Install the bolt.

      7.0 N*m

      71 kgf*cm

      62 in.*lbf

  5. INSTALL AIR CLEANER CASE SUB-ASSEMBLY

  6. INSTALL AIR CLEANER CAP SUB-ASSEMBLY

  7. INSTALL NO. 2 CYLINDER HEAD COVER

  8. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click hereClick hereClick hereClick hereClick hereClick here