ECM INSTALLATION
PROCEDURE
INSTALL NO. 2 ECM BRACKET
Install the No. 2 ECM bracket to the ECM with the 2 screws.
3.0 N*m
31 kgf*cm
27 in.*lbf
INSTALL ECM BRACKET
Install the No. 1 ECM bracket to the ECM with the 2 screws.
3.0 N*m
31 kgf*cm
27 in.*lbf
INSTALL ECM
Install the ECM with the 2 bolts.
12.5 N*m
127 kgf*cm
9 ft.*lbf
Note:If a component has been dropped or subjected to a strong impact, replace it.
-
Connect the 2 ECM connectors and lower the 2 levers.
Note:When connecting the connectors, make sure that dirt, water or other foreign matter does not contact the connecting parts of the connectors.
Make sure that the 2 levers are locked securely.
Install the wire harness clamp.
INSTALL NO. 1 AIR CLEANER INLET
-
Install the bolt.
7.0 N*m
71 kgf*cm
62 in.*lbf
-
INSTALL AIR CLEANER CASE SUB-ASSEMBLY
INSTALL AIR CLEANER CAP SUB-ASSEMBLY
INSTALL NO. 2 CYLINDER HEAD COVER
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click hereClick hereClick hereClick hereClick hereClick here