КЛАПАН ПЕРЕКЛЮЧЕНИЯ ПОДАЧИ ВОЗДУХА (для моделей с вспомогательной системой подачи воздуха в нейтрализатор) ПРОВЕРКА


  1. INSPECT AIR SWITCHING VALVE ASSEMBLY


    1. A01DY8ZE01

      Measure the resistance of the air switching valve.

      Standard resistance
      Tester Connection Specified Condition
      1 - 2 4.5 to 5.5 Ω at 20°C (68°F)

      1 - Body ground

      2 - Body ground

      1 MΩ or higher

      If the result is not as specified, replace the air switching valve assembly.

    2. A01DY42E02

      Check operation of the air switching valve.


      1. Check that air does not flow from port A to port B.

        If the result is not as specified, replace the air switching valve assembly.

      2. A01DXS2E01

        Apply battery voltage across terminals 1 and 2.

      3. Check that air flows from port A to port B.

        If the result is not as specified, replace the air switching valve assembly.