CAUTION / NOTICE / HINT
Tech Tips
Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
w/ Canister Pump Module:
w/o Canister Pump Module:
PROCEDURE
INSTALL MASS AIR FLOW METER SUB-ASSEMBLY
Tech Tips
Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
w/ Canister Pump Module:
w/o Canister Pump Module:
Install the 2 mass air flow meter sub-assemblies with the 4 screws.
Note
If the mass air flow meter sub-assembly has been struck or dropped, replace it.
If reusing the mass air flow meter sub-assembly, be sure to inspect the O-ring.
Make sure that the O-ring is not cracked or does not move out of place during installation.
Connect the 2 mass air flow meter sub-assembly connectors.
INSTALL LOWER RADIATOR AIR DEFLECTOR
INSTALL UPPER RADIATOR SUPPORT SEAL
INSTALL RADIATOR COVER PLATE
INSTALL V-BANK COVER SUB-ASSEMBLY