MASS AIR FLOW METER INSTALLATION

CAUTION / NOTICE / HINT

Tech Tips

Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.


PROCEDURE


  1. INSTALL MASS AIR FLOW METER SUB-ASSEMBLY

    Tech Tips

    Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.



    1. Install the 2 mass air flow meter sub-assemblies with the 4 screws.

      Note


      • If the mass air flow meter sub-assembly has been struck or dropped, replace it.

      • If reusing the mass air flow meter sub-assembly, be sure to inspect the O-ring.

      • Make sure that the O-ring is not cracked or does not move out of place during installation.

    2. Connect the 2 mass air flow meter sub-assembly connectors.

  2. INSTALL LOWER RADIATOR AIR DEFLECTOR

    Click here

  3. INSTALL UPPER RADIATOR SUPPORT SEAL

    Click here

  4. INSTALL RADIATOR COVER PLATE

    Click here

  5. INSTALL V-BANK COVER SUB-ASSEMBLY

    Click here