RELAY INSPECTION
PROCEDURE
INSPECT TSS C HTR RELAY
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 - 5
Battery voltage not applied between terminals 1 and 2
10 kΩ or higher
3 - 5
Battery voltage applied between terminals 1 and 2
Below 1 Ω
1 - 5
Battery voltage not applied between terminals 1 and 2
10 kΩ or higher
2 - 3
Battery voltage not applied between terminals 1 and 2
10 kΩ or higher
If the result is not as specified, replace the TSS C HTR relay.
-