8GR-FKS STARTING SERVICE DATA

STARTER ASSEMBLY
Tester Connection Condition Specified Condition
Battery positive (+) terminal - Terminal 30 - Terminal SL2 11.5 V 130 A or less
Segment - Segment Always Below 1 Ω
Segment - Starter armature core 10 kΩ or higher
Commutator runout Maximum runout 0.05 mm (0.00197 in.)
Commutator diameter Standard diameter 29 mm (1.14 in.)
Minimum Diameter 28 mm (1.10 in.)
Undercut depth Standard undercut depth 0.7 mm (0.0276 in.)
Minimum undercut depth 0.4 mm (0.0157 in.)
Brush length Standard length 14.4 mm (0.567 in.)
Minimum length 9.0 mm (0.354 in.)

A - B

A - C

B - D

C - D

Always 10 kΩ or higher

A - D

B - C

Below 1 Ω
Brush spring load Standard spring load 22.3 to 27.3 N (2.27 to 2.78 kgf, 5.0 to 6.1 lbf)
Minimum spring load 13.8 N (1 kgf, 3.1 lbf)
Terminal SL1 - Magnet switch body Always Below 1 Ω
Terminal SL2 - Magnet switch body Always Below 2 Ω
ENGINE SWITCH
Tester Connection Condition Specified Condition

5 (SS1) - 6 (AGND)

1 (SS2) - 6 (AGND)

Not pushed 10 kΩ or higher
Pushed Below 1 Ω

Battery positive (+) → Terminal 9 (SWIL)

Battery negative (-) → Terminal 6 (AGND)

Illuminates
RELAY
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω