CRANKSHAFT POSITION SENSOR (w/ EGR Cooler) INSPECTION


  1. INSPECT CRANKSHAFT POSITION SENSOR

    A01DVSLE01

    1. Measure the resistance between the terminals.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 2 Approx. 20°C (68°F) 1,850 to 2,450 Ω

      • If the result is not as specified, replace the sensor.