COOLING FAN MOTOR ON-VEHICLE INSPECTION
PROCEDURE
INSPECT COOLING FAN MOTOR
Disconnect the cooling fan motor connector.
Check that the fan rotates smoothly by hand.
Check that the cooling fan motor turns smoothly when the battery is connected to the cooling fan motor connector.
-
Measure the current according to the value(s) in the table below.
Standard Current
Tester Connection
Condition
Specified Condition
2
20°C (68°F)
12.2 to 15.7 A
Table 1. Text in Illustration *a
Component without harness connected
(Cooling Fan Motor)
If the result is not as specified, replace the cooling fan motor.
Reconnect the cooling fan motor connector.
INSPECT NO. 2 COOLING FAN MOTOR
Disconnect the No. 2 cooling fan motor connector.
Check that the No. 2 fan rotates smoothly by hand.
Check that the No. 2 cooling fan motor turns smoothly when the battery is connected to the No. 2 cooling fan motor connector.
-
Measure the current according to the value(s) in the table below.
Standard Current
Tester Connection
Condition
Specified Condition
2
20°C (68°F)
12.2 to 15.7 A
Table 2. Text in Illustration *a
Component without harness connected
(No. 2 Cooling Fan Motor)
If the result is not as specified, replace the No. 2 cooling fan motor.
Reconnect the No. 2 cooling fan motor connector.