AUTOMATIC HEADLIGHT BEAM LEVEL CONTROL SYSTEM
The headlight leveling ECU assembly operates in fail-safe mode if an abnormal condition such as those listed below has been detected, and keep the last low beam status.
| Item | Abnormality Detection Condition | Return Condition | Warning Indicator |
|---|---|---|---|
| Height control sensor power source voltage | Abnormal height control sensor power source voltage (4.6 V or less, or 6.25 V or more) is detected. | Voltage of 4.61 to 6.24 V is detected | Illuminated |
| Height control sensor signal voltage | Abnormal height control sensor signal voltage (0.25 V or less, or 4.75 V or more) is detected. | Voltage of 0.26 to 4.74 V is detected | |
| IG power source voltage | Abnormal high power source voltage (18.1 V or more) is detected. | Voltage of 17.5 V or less is detected | Not illuminated |
| Abnormal low power source voltage (9.0 V or less) is detected. | Voltage of 9.3 V or more is detected for 0.1 seconds | Not illuminated | |
| Abnormal height control sensor signal while initialization | Initialization is performed outside the valid range of the voltage for initialization. | Initialization is successfully completed within the valid range of the voltage for initialization. | Illuminated |