BLOWER RESISTOR(for Manual Air Conditioning System) INSPECTION

PROCEDURE

  1. INSPECT BLOWER RESISTOR

    1. E108912E26

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Table 1. for LHD

      Tester Connection

      Condition

      Specified Condition

      1 (HI) - 4 (E)

      Always

      3.12 to 3.60 Ω

      3 (M2) - 4 (E)

      Always

      1.45 to 1.67 Ω

      2 (M1) - 4 (E)

      Always

      0.52 to 0.60 Ω

      Table 2. for RHD

      Tester Connection

      Condition

      Specified Condition

      4 (HI) - 1 (E)

      Always

      3.12 to 3.60 Ω

      2 (M2) - 1 (E)

      Always

      1.45 to 1.67 Ω

      3 (M1) - 1 (E)

      Always

      0.52 to 0.60 Ω

      Table 3. Text in Illustration

      *1

      Component without harness connected

      (Blower Resistor)

      *2

      for LHD

      *3

      for RHD

      If the result is not as specified, replace the blower resistor.