| DTC Code | DTC Name |
|---|---|
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit |
| P0AC1-123 | Hybrid Battery Pack Current Sensor Circuit Low |
| P0AC2-123 | Hybrid Battery Pack Current Sensor Circuit High |
| P0B10-123 | Hybrid Battery Pack Current Sensor "B" Circuit Low |
| P0B11-123 | Hybrid Battery Pack Current Sensor "B" Circuit High |
DESCRIPTION
A battery current sensor, which is mounted on the positive cable side of each hybrid battery junction block assembly, detects the current flowing to or from the battery pack. The battery current sensor sends a voltage, which varies between 0 and 5 V in proportion to the amperage, to the IB0 terminal of the battery smart unit. Similarly, it sends a voltage, which varies between 0 and 5 V in inverse proportion to the amperage, into the IB1 terminal of the battery smart unit. When the voltage of the IB0 terminal is below 2.8 V and the voltage of the IB1 terminal is above 2.2 V, this indicates that the HV battery is being discharged. Meanwhile, when the voltage of the IB0 terminal is above 2.8 V and the voltage of the IB1 terminal is below 2.2 V, this indicates that the HV battery is being charged. The battery smart unit sends the signals from its IB0 and IB1 terminals to the power management control ECU. The power management control ECU determines the charging and discharging amperage of the HV battery based on the received signals and calculates the SOC of the HV battery using the cumulative amperage value.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0ABF P0AC1 P0AC2 P0B10 P0B11 |
123 | When the battery current sensor is abnormal (1 trip detection) |
|
WIRING DIAGRAM
| *a | Battery Current Sensor (Hybrid Battery Junction Block Assembly) |
| *b | Battery Smart Unit |
Refer to the wiring diagram for DTC U029A-123 Click here.
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
Tech Tips
If a short to +B occurs in the battery temperature sensor, battery current sensor or intake air temperature sensor, the following DTCs may be output simultaneously.
| DTC No. | Relevant Diagnosis |
|---|---|
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit |
| P0A9E-123 | Hybrid Battery Temperature Sensor "A" Circuit High |
| P0AC8-123 | Hybrid Battery Temperature Sensor "B" Circuit High |
| P0ACD-123 | Hybrid Battery Temperature Sensor "C" Circuit High |
| P0AEB-123 | Hybrid Battery Temperature Sensor "D" Circuit High |
| P0BC5-123 | Hybrid Battery Temperature Sensor "E" Circuit High |
| P0C36-123 | Hybrid Battery Temperature Sensor "F" Circuit High |
| P0AAF-123 | Hybrid Battery Pack Air Temperature Sensor "A" Circuit High |
| P0AB4-123 | Hybrid Battery Pack Air Temperature Sensor "B" Circuit High |
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs Click here.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO DTC CHART (P0AFC-123) Click here |
| A |
|
CHECK HARNESS AND CONNECTOR (B AND IGCT VOLTAGE)
Note
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly Click here.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Note
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| *a | Component with harness connected (Battery Smart Unit) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
As there might be an intermittent malfunction in the battery voltage sensor power source circuit, inspect the following even if the measured voltage is as specified:
Installation condition of fuse(s) (before removing fuse(s)) (IGCT circuit)
Fuse condition (before and after removing fuse(s)) (IGCT circuit)
Connection condition of connectors (IGCT circuit)
Wire harness condition (IGCT circuit)
Wire harness condition (GND circuit)
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery shield sub-assembly.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (SMART UNIT POWER SOURCE CIRCUIT) |
| OK |
|
CHECK HARNESS AND CONNECTOR (BATTERY SMART UNIT - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)
Note
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 2 hybrid battery shield sub-assembly Click here.
Disconnect the z25 hybrid battery junction block assembly connector.
| *a | Rear view of wire harness connector (to Battery Smart Unit) |
| *b | Front view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Disconnect the z24 battery smart unit connector.
Measure the resistance according to the value(s) in the tables below.
| Standard Resistance (Check for Open) | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Reconnect the z25 hybrid battery junction block assembly connector.
Reconnect the z24 battery smart unit connector.
Install the No. 2 hybrid battery shield sub-assembly.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR OR HV BATTERY |
| OK |
|
CHECK BATTERY SMART UNIT (VIB VOLTAGE)
Note
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly Click here.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Note
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| *a | Component with harness connected (Battery Smart Unit) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery shield sub-assembly.
| NG |
|
REPLACE BATTERY SMART UNIT Click here |
| OK |
|
CHECK BATTERY SMART UNIT (BATTERY CURRENT SENSOR OUTPUT VOLTAGE)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly Click here.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Note
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| *a | Component with harness connected (Battery Smart Unit) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the No. 1 hybrid battery shield sub-assembly.
| OK |
|
REPLACE BATTERY SMART UNIT Click here |
| NG |
|
REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY Click here |