ECM(w/ Glow Plug Controller) INSTALLATION
PROCEDURE
INSTALL NO. 2 ECM BRACKET
Install the No. 2 ECM bracket to the ECM with the 2 screws.
3.0 N*m
31 kgf*cm
27 in.*lbf
INSTALL NO. 1 ECM BRACKET
Install the No. 1 ECM bracket to the ECM with the 2 screws.
3.0 N*m
31 kgf*cm
27 in.*lbf
INSTALL ECM
Engage the guide and install the ECM with the 2 bolts.
12.5 N*m
127 kgf*cm
9 ft.*lbf
Note:If the ECM has been struck or dropped, replace it.
-
Connect the 2 ECM connectors and lower the 2 levers.
Note:When connecting the ECM connectors, make sure that the connecting parts of the ECM connectors are free of dirt, water or other foreign matter.
Be sure to securely connect the ECM connectors.
INSTALL NO. 1 AIR CLEANER INLET
Install the No. 1 air cleaner inlet with the bolt.
7.0 N*m
71 kgf*cm
62 in.*lbf
INSTALL AIR CLEANER CASE SUB-ASSEMBLY
INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE
INSTALL NO. 1 ENGINE COVER (w/ No. 1 Engine Cover)
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
PERFORM REGISTRATION
PERFORM INITIALIZATION