ECM(w/o Glow Plug Controller) INSTALLATION
PROCEDURE
INSTALL NO. 2 ECM BRACKET
Install the No. 2 ECM bracket to the ECM with the 2 screws.
6.0 N*m
61 kgf*cm
53 in.*lbf
INSTALL NO. 1 ECM BRACKET
Install the No. 1 ECM bracket to the ECM with the 2 screws.
6.0 N*m
61 kgf*cm
53 in.*lbf
INSTALL ECM
Install the ECM with the 2 bolts.
12.5 N*m
127 kgf*cm
9 ft.*lbf
Connect the 2 connectors from the ECM, and lower the 2 levers.
Note:When connecting the connectors, make sure that dirt, water or other foreign matter does not get caught between the connectors and other parts.
Make sure that the 2 levers are securely lowered.
INSTALL NO. 1 AIR CLEANER INLET
Install the No. 1 air cleaner inlet with the bolt.
7.0 N*m
71 kgf*cm
62 in.*lbf
INSTALL AIR CLEANER CASE SUB-ASSEMBLY
INSTALL AIR CLEANER CAP SUB-ASSEMBLY
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
INSTALL NO. 1 ENGINE COVER (w/ No. 1 Engine Cover)
PERFORM REGISTRATION
PERFORM INITIALIZATION