CHARGING SYSTEM TERMINALS OF ECM
CHECK ECM
Tip:The standard voltage and resistance between each pair of the ECM terminals is shown in the table below. The appropriate conditions for checking each pair of the terminals is also indicated. The result of checks should be compared with the standard voltage and resistance for each pair of the terminals as displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.
Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
A62-1 (BATT) - B93-59 (E1)
W - BR
Battery (for measuring battery voltage and for ECM memory)
Always
11 to 14 V
B93-59 (E1) - Body ground
BR - Body ground
Earth (ground) circuit of ECM
Always
Below 1 Ω
B93-61 (LIN) - Body ground
L - Body ground
LIN communication line
Ignition switch off
(while LIN communication is stopped)
10 kΩ or higher