STOP AND START SYSTEM CANCEL SWITCH ASSEMBLY INSPECTION
PROCEDURE
INSPECT ECO RUN CANCEL SWITCH ASSEMBLY
-
*a
Component without harness connected
(Eco Run Cancel Switch Assembly)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Switch Condition
Specified Condition
8 (ECU) - 5 (E)
Pushed
Below 1 Ω
Not pushed
10 kΩ or higher
If the result is not as specified, replace the eco run cancel switch assembly.
-
*a
Component without harness connected
(Eco Run Cancel Switch Assembly)
Apply battery voltage between the terminals of the switch, and check the illumination condition of the eco run cancel switch assembly.
OK
Measurement Condition
Specified Condition
Battery positive (+) → 7 (ILL+)
Battery negative (-) → 6 (ILL-)
Illuminates