PROCEDURE
REMOVE NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY
REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY
w/ PTC Heater:
| *A | w/ PTC Heater |
| *1 | Quick Heater Connector Screw |
Remove the quick heater connector screw.
Disengage the clamp and disconnect the connector.
Remove the 3 screws and blower motor with fan sub-assembly.
Note
When removing the blower motor with fan sub-assembly, do not damage it or allow it to receive an impact.