ЭЛЕКТРОВАКУУМНЫЙ КЛАПАН (для моделей, работающих на неэтилированном бензине) ПРОВЕРКА


  1. INSPECT VACUUM SWITCHING VALVE (for EVAP)


    1. A01DYXPE01

      Measure the resistance of the VSV.

      Standard resistance
      Tester Connection Specified Condition
      1 - 2 26 to 30 Ω at 20°C (68°F)

      1 - Body ground

      2 - Body ground

      10 MΩ or higher

      If the result is not as specified, replace the VSV.

    2. A01E0SDE04

      Check operation of the VSV.


      1. Check that air does not flow from port E to port F.

      2. A01E09ZE01

        Apply battery voltage across terminals 1 and 2.

      3. Check that air flows from port E to port F.

        If the result is not as specified, replace the VSV.