HEATER FUEL PUMP INSTALLATION
PROCEDURE
INSTALL HEATER PUMP ASSEMBLY
Connect the connector to the heater pump assembly.
Install the heater pump assembly and while pushing the bracket to the stud bolt, tighten the nut as shown in the illustration.
*1
Stud Bolt
-
-
*a
Marking
-
-
9.8 N*m
100 kgf*cm
87 in.*lbf
Align the markings on each hose and pipe as shown in the illustration and connect them with the clips.
INSTALL AIR CLEANER CAP SUB-ASSEMBLY
INSTALL NO. 1 ENGINE COVER