AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P0798
| DTC Code | DTC Name |
|---|---|
| P0798 | Pressure Control Solenoid "C" Electrical (Shift Solenoid Valve SL3) |
DESCRIPTION
Changing from 1st to 6th is performed by the TCM turning shift solenoid valves SL1, SL2, SL3, SL4 and SL on and off. If an open or short circuit occurs in any of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
MIL |
Memory |
|---|---|---|---|---|---|
P0798 |
Pressure Control Solenoid "C" Electrical (Shift Solenoid Valve SL3) |
An open or short circuit (output signal duty is 0% or 100%) is detected by the TCM in the shift solenoid valve SL3 circuit while driving and shifting gears (SL3 output signal duty is more than 0% and less than 100% under normal conditions) (1-trip detection logic). |
|
Comes on |
DTC stored |
MONITOR DESCRIPTION
The TCM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem and illuminates the MIL and stores the DTC. And the TCM performs the fail-safe function and turns the other normal shift solenoid valves on or off. (In case of an open or short circuit, the TCM stops sending current to the circuit.)
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Perform registration and/or initialization when parts related to the automatic transaxle are replaced.
The following table shows normal operation of shift solenoid valve SL3 when the shift lever is in D:
TCM gear shift command |
1st |
2nd |
3rd |
4th |
5th |
6th |
Shift solenoid valve SL3 |
OFF |
ON |
OFF |
OFF |
OFF |
ON |
PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL3)
-
*a
Component without TCM connected
(Transmission Wire)
Remove the TCM.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
16 (SL3+) - 15 (SL3-)
20°C (68°F)
5.0 to 5.6 Ω
16 (SL3+) - Body ground
Always
10 kΩ or higher
15 (SL3-) - Body ground
Always
10 kΩ or higher
16 (SL3+) - All other terminals except 15 (SL3-)
Always
10 kΩ or higher
15 (SL3-) - All other terminals except 16 (SL3+)
Always
10 kΩ or higher
Result
Proceed to
OK
NG
-
INSPECT SHIFT SOLENOID VALVE SL3
-
*1
Shift Solenoid Valve SL3
Remove shift solenoid valve SL3.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK
Measurement Condition
Specified Condition
Battery positive (+) with a 21 W bulb → Terminal 1
Battery negative (-) → Terminal 2
Valve moves and makes an operating noise
Result
Proceed to
OK
NG
-