AIR CONDITIONING SYSTEM, Diagnostic DTC:B1411/11
| DTC Code | DTC Name |
|---|---|
| B1411/11 | Room Temperature Sensor Circuit |
DESCRIPTION
The cooler thermistor (room temperature sensor) for the front seat is installed in the instrument panel to detect the room temperature and control the heater and air conditioner auto mode. The resistance of the room temperature sensor changes in accordance with the front room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the room temperature sensor and reads voltage changes as the resistance of the room temperature sensor changes. This sensor also sends the appropriate signals to the air conditioning amplifier assembly.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
Memory |
Note |
|---|---|---|---|---|---|
B1411/11 |
Room Temperature Sensor Circuit |
An open or short in the cooler thermistor (room temperature sensor) circuit. |
|
Stored (4 seconds or more) |
If the front room temperature is approx. -18.6°C (-1.48°F) or less, DTC B1411/11 may be stored even though the system is normal. |
WIRING DIAGRAM
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (ROOM TEMPERATURE SENSOR)
Use the Data List to check if the cooler thermistor (room temperature sensor) is functioning properly
Body Electrical > Air Conditioner > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Room Temperature Sensor
Cooler thermistor (room temperature sensor)
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual room temperature for front seat displayed
Open in the circuit: -6.5°C (20.3°F).
Short in the circuit: 57.25°C (135.05°F).
OK
The display is as specified in the normal condition column.
Result
Result
Proceed to
OK (When troubleshooting according to problem symptoms table)
A
OK (When troubleshooting according to the DTC)
B
NG
C
INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)
-
*a
Sensing Portion
*b
Resistance
*c
Allowable Range
*d
Temperature
Remove the cooler thermistor (room temperature sensor)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
10°C (50°F)
3.00 to 3.73 kΩ
15°C (59°F)
2.45 to 2.88 kΩ
20°C (68°F)
1.95 to 2.30 kΩ
25°C (77°F)
1.60 to 1.80 kΩ
30°C (86°F)
1.28 to 1.47 kΩ
35°C (95°F)
1.00 to 1.22 kΩ
40°C (104°F)
0.80 to 1.00 kΩ
45°C (113°F)
0.65 to 0.85 kΩ
50°C (122°F)
0.50 to 0.70 kΩ
55°C (131°F)
0.44 to 0.60 kΩ
60°C (140°F)
0.36 to 0.50 kΩ
Note:Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tip:As the temperature increases, the resistance decreases (refer to the graph).
Result
Result
OK
NG
-
CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
Disconnect the G15 sensor connector.
Disconnect the G13 amplifier connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
G15-1 - G13-29 (TR)
Always
Below 1 Ω
G15-2 - G13-34 (SG-1)
G13-29 (TR) - Body ground
Always
10 kΩ or higher
G13-34 (SG-1) - Body ground
Result
Result
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR