FRONT BLOWER MOTOR INSPECTION


  1. INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY

    A01DZPBE01
    Text in Illustration
    *a

    Component without harness connected

    (Blower Motor with Fan Sub-assembly)


    1. Check the operation.


      1. Apply battery voltage to the blower motor and check the operation of the motor.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 2

        Battery negative (-) → Terminal 1

        Blower motor operates smoothly

        If the result is not as specified, replace the blower motor with fan sub-assembly.