AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P2716

DTC Code DTC Name
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

DESCRIPTION

Refer to DTC P2714.

Click here

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

MIL

Memory

P2716

Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

An open or short is detected in the shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).

  • Open or short in shift solenoid valve SLT circuit

  • Shift solenoid valve SLT

  • TCM

Comes on

DTC stored

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the TCM interprets this as a fault. The TCM will turn on the MIL and store the DTC.

WIRING DIAGRAM

C279421E04

CAUTION / NOTICE / HINT

Note:

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click here

PROCEDURE

  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)

    1. C207057C19

      *a

      Component without TCM connected

      (Transmission Wire)

      Remove the TCM.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      12 (SLT+) - 7 (SLT-)

      20°C (68°F)

      5.0 to 5.6 Ω

      12 (SLT+) - Body ground

      Always

      10 kΩ or higher

      7 (SLT-) - Body ground

      Always

      10 kΩ or higher

      12 (SLT+) - All other terminals except 7 (SLT-)

      Always

      10 kΩ or higher

      7 (SLT-) - All other terminals except 12 (SLT+)

      Always

      10 kΩ or higher

    Result

    Proceed to

    OK

    NG

    OK

    REPLACE TCM

    NG
  2. INSPECT SHIFT SOLENOID VALVE SLT

    1. C197715C16

      *1

      Shift Solenoid Valve SLT

      Remove shift solenoid valve SLT.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      1 - 2

      20°C (68°F)

      5.0 to 5.6 Ω

    3. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK

      Measurement Condition

      Specified Condition

      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise

    Result

    Proceed to

    OK

    NG

    OK

    REPLACE TRANSMISSION WIRE

    NG

    REPLACE SHIFT SOLENOID VALVE SLT