ECM INSTALLATION
PROCEDURE
INSTALL ECM
Install the No. 1 ECM bracket and No. 2 ECM bracket to the ECM with the 4 screws.
3.0 N*m
31 kgf*cm
27 in.*lbf
Install the ECM with bracket with the 3 bolts.
6.5 N*m
66 kgf*cm
58 in.*lbf
Connect the 2 ECM connectors and lower the 2 levers.
Note:When connecting the ECM connector, make sure that dirt, water or other foreign matter is not stuck between the ECM connector and ECM.
Make sure that the 2 levers are securely lowered.
INSTALL AIR CLEANER CASE
INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
INSTALL AIR CLEANER CAP SUB-ASSEMBLY
INSTALL NO. 1 ENGINE COVER
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click hereClick hereClick hereClick hereClick hereClick here
PERFORM REGISTRATION
PERFORM INITIALIZATION
PERFORM THROTTLE VALVE FULLY CLOSED POSITION LEARNING