ABSORBER CONTROL SWITCH INSPECTION

PROCEDURE


  1. INSPECT SATELLITE SWITCH SET (ABSORBER CONTROL SWITCH)


    1. B006FA1C01
      *a

      Component without harness connected

      (No. 2 Satellite Switch Set (Absorber Control Switch))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      G49-3 (P) - G49-7 (GND) Combination switch assembly knob turned and held at S/S+ position Below 50 Ω
      G49-3 (P) - G49-7 (GND) Combination switch assembly knob not turned to S/S+ position 10 kΩ or higher
      G49-2 (B) - G49-7 (GND) Normal/Custom mode switch pushed and held Below 50 Ω
      G49-2 (B) - G49-7 (GND) Normal/Custom mode switch not pushed 10 kΩ or higher

      If the result is not as specified, replace the No. 2 satellite switch set (absorber control switch).

    2. B006FA1C05
      *a

      Component without harness connected

      (No. 2 Satellite Switch Set (Absorber Control Switch))

      Apply battery voltage between the terminals of the switch, and check the illumination condition of the absorber control switch (combination switch assembly).

      Standard
      Tester Connection Specified Condition

      Battery positive (+) → G49-1 (ILL+)

      Battery negative (-) → G49-8 (ILL-)

      Illuminates

      If the result is not as specified, replace the No. 2 satellite switch set (absorber control switch).