PROCEDURE
INSPECT NO. 1 COOLER THERMISTOR
| *a | Component without harness connected (No. 1 Cooler Thermistor) |
| *b | Sensing Portion |
| *c | Resistance (kΩ) |
| *d | Temperature (°C (°F)) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Hold the sensor only by its connector. Touching the sensor may change the resistance value.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tech Tips
As the temperature increases, the resistance decreases (See the graph).
If the result is not as specified, there may be a malfunction in the No. 1 cooler thermistor.