HYBRID CONTROL SYSTEM, Diagnostic DTC:P3233-750

DTC Code DTC Name
P3233-750 Open or Short to B+ in Blocking of HV Gate Connection

DESCRIPTION

Refer to the description for DTC P3232-749 Click here.

DTC No. INF Code DTC Detection Condition Trouble Area
P3233 750 Open or short to +B in the emergency shutdown signal line when the IGBTs are operating.
  • Wire harness or connector

  • Power management control ECU

  • Inverter with converter assembly

WIRING DIAGRAM

Refer to the wiring diagram for DTC P3232-749 Click here.

CAUTION / NOTICE / HINT

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

Tech Tips

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


  1. Turn the power switch on (IG) and wait for 5 seconds or more.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A59 inverter with converter assembly connector.

    3. Disconnect the A22 power management control ECU connector.

    4. Connect the cable to the negative (-) auxiliary battery terminal.

    5. Turn the power switch on (IG).

    6. Measure the voltage according to the value(s) in the table below.

      A005D5QE01
      Standard Voltage
      Tester Connection Condition Specified Condition
      A22-31 (HSDN) - Body ground Power switch on (IG) Below 1 V
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *b

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Note

      Turning the power switch on (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Turn the power switch off.

    9. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A22-31 (HSDN) - A59-31 (HSDN) Power switch off Below 1 Ω
    10. Reconnect the A59 inverter with converter assembly connector.

    11. Reconnect the A22 power management control ECU connector.


    NG
    OK
  2. CHECK INVERTER WITH CONVERTER ASSEMBLY

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A59 inverter with converter assembly connector.

    3. A005EF7E03
      Text in Illustration
      *a

      Component without harness connected

      (Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A59-31 (HSDN) - A59-10 (+B) Power switch off 80 Ω or higher
      A59-31 (HSDN) - A59-9 (+B2) Power switch off 80 Ω or higher
      A59-31 (HSDN) - A59-28 (GND1) Power switch off 2.65 to 3.55 kΩ
    4. Reconnect the A59 inverter with converter assembly connector.


    OK
    NG