A25A-FKS LUBRICATION SERVICE DATA

Oil Pressure
Condition Specified Condition
Idling

60 kPa (0.6 kgf/cm2, 8.7 psi) or higher

2000 rpm

190 kPa (1.9 kgf/cm2, 28 psi) or higher

4000 rpm

300 kPa (3.1 kgf/cm2, 44 psi) or higher

Oil Pressure Switching Valve Assembly
Tester Condition Condition Specified Condition
1 - 2 20°C (68°F) 6.2 to 8.2 Ω
Engine Oil Level Sensor
Tester Condition Condition Specified Condition
1 - Engine oil level sensor body ON Below 1 Ω
OFF 10 kΩ or higher
Oil Pump
Item Condition Specified Condition
Oil pump rotor Standard side clearance (Oil pump driven rotor side) 0.025 to 0.070 mm (0.000984 to 0.00276 in.)
Standard side clearance (Oil pump regulator ring side) 0.025 to 0.075 mm (0.000984 to 0.00295 in.)