ROOM LIGHT INSPECTION
PROCEDURE
INSPECT NO. 1 ROOM LIGHT ASSEMBLY (w/ Room Light (for Push Switch Type))
-
*a
Component without harness connected
(No. 1 Room Light Assembly)
Inspect the room lights.
Apply battery voltage to each terminal of No. 1 room light assembly connector and check the operation of the room lights.
Result
Connection
Condition
Specified Condition
Battery positive (+) → 4 (B)
Battery negative (-) → 3 (E)
Room light switches off
Room light LH and RH do not come on
Room light switch LH on
Room light LH comes on
Room light switch RH on
Room light RH comes on
Battery positive (+) → 4 (B)
Battery negative (-) → 2 (CTY)
Room light switches off
Room light LH and RH come on
Room light switch LH on
Room light LH do not come on
Room light switch RH on
Room light RH do not come on
If the result is not as specified, replace the bulb or No. 1 room light assembly.
-