ROOM LIGHT INSPECTION

PROCEDURE

  1. INSPECT NO. 1 ROOM LIGHT ASSEMBLY (w/ Room Light (for Push Switch Type))

    1. E228049C06

      *a

      Component without harness connected

      (No. 1 Room Light Assembly)

      Inspect the room lights.

      1. Apply battery voltage to each terminal of No. 1 room light assembly connector and check the operation of the room lights.

        Result

        Connection

        Condition

        Specified Condition

        Battery positive (+) → 4 (B)

        Battery negative (-) → 3 (E)

        Room light switches off

        Room light LH and RH do not come on

        Room light switch LH on

        Room light LH comes on

        Room light switch RH on

        Room light RH comes on

        Battery positive (+) → 4 (B)

        Battery negative (-) → 2 (CTY)

        Room light switches off

        Room light LH and RH come on

        Room light switch LH on

        Room light LH do not come on

        Room light switch RH on

        Room light RH do not come on

        If the result is not as specified, replace the bulb or No. 1 room light assembly.