GLOW PLUG CONTROLLER INSTALLATION

PROCEDURE


  1. INSTALL NO. 1 GLOW PLUG CONTROLLER BRACKET


    1. Install the No. 1 glow plug controller bracket to the glow plug controller with the 2 screws.

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
  2. INSTALL GLOW PLUG CONTROLLER


    1. Connect the 4 connectors.

    2. Install the glow plug controller with the 2 bolts.

      Torque:
      20 N*m  { 204 kgf*cm, 15 ft.*lbf }
  3. INSTALL NO. 2 AIR CLEANER INLET


    1. Install the No. 2 air cleaner inlet with the bolt.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
  4. INSTALL NO. 1 AIR CLEANER INLET


    1. Install the No. 1 air cleaner inlet with the clip.

  5. INSTALL AIR CLEANER CASE SUB-ASSEMBLY

    Click here

  6. INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

  7. INSTALL AIR CLEANER CAP SUB-ASSEMBLY

    Click here

  8. INSTALL BATTERY

  9. INSTALL BATTERY INSULATOR

  10. INSTALL BATTERY CLAMP SUB-ASSEMBLY

    Click here

  11. CONNECT CABLE TO POSITIVE BATTERY TERMINAL

  12. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.